Cooling Towers


COOLING TOWER

There are two type of cooling tower in which we have delt e.i. Round shape cooling tower and Square type cooling tower.

1. Round shape cooling Towers

ICT (Induced Draft Counter flow Cooling Tower) Round shaped or popularly known as bottle type are designed to cool industrial re-cycled process water from temperature of 50 degrees to temperature of 4 plus the prevailing Wet Bulb temperature of the region

The tower design incorporates hot water inlet at the bottom collection sump circulated vertically to the mechanical rotary sprinkler located above the fill media. The inlet water pressure rotate the sprinkler, having extended arm pipes with orifices to disperse water uniformly over the fill media.

The fan directly coupled to the motor, during operations takes away the heat by induced draft mechanism. Air is drawn from the lower air in take area & is induced to travel through the fill media thus taking away the latent heat from the water passing through the fill media. Portion of water evaporated, removes the heat from the remaining water. The warm moist air is drawn through the fan deck is discharged to the atmosphere. Cold water, collected at the collection sump, is re-circulated to the source.

Principal Function

Warm water from the heat source is circulated to the water distribution system. The water is dispersed uniformly over the wet deck fill by means of orifice of the extended arm pipes of the rotary sprinkler. Simultaneously, air is drawn in through the air inlet louvers at the base of the tower and travels upward through the wet deck fill opposite to the direction of the water flow. A small portion of the water is evaporated which removes the heat from the remaining water. The warm moist air is drawn to the top of the cooling tower by the fan and discharged to the atmosphere. The cool water drains to the basin at the bottom of the tower and is returned to the heat source.

Technical Function

The tower design incorporates water inlets at the bottom collection sump through which water is circulated vertically to the mechanical rotary sprinkler located above the fill media. The inlet water forces the rotary sprinkler, having extended arm pipes with orifices to rotate about and disperse water uniformly over the fill media.

The fan directly coupled to the motor is located on the top and during operations take away the heat by induced draft mechanism. Air is drawn from the lower air in take area & is forced to travel through the fill media vertically. During this process it takes away the heat from the water passing through the fill media. A small portion of the water is evaporated which removes the heat from the remaining water. The warm moist air is drawn through the fan deck, by the fan and discharged to the atmosphere. Cold water is collected at the collection sump having the outlet connection through which cold water is re-circulated to the application.

The distinguishing features of our product are compact design Honey comb type PVC fills, with varying flute sizes, to provide maximum contact surface area and heat transfer surface per unit volume.


2. SQUARE SHAPE COOLING TOWER

ICT-square shaped towers cool the re-cycled water. The towers blend easily with architectural surroundings, giving a unique aesthetic appearance.

Designed to cool industrial re-cycled process water from temperature of 50 degrees to temperature of 4 plus the prevailing Wet Bulb temperature of the region. The design incorporate the static spray nozzle distribution to atomize water in to a mist state and ensure uniformity in water dispersion and are easy to maintain even during the tower operations.

The hot water from the application is dispersed uniformly over the wet deck fill by means of static spray non clog nozzles. Simultaneously, air is induced through the fill media thus taking away the latent heat from the water passing through the fill media. Portion of water evaporated, removes the heat from the remaining water. The warm moist air is drawn through the fan deck is discharged to the atmosphere. Cold water, collected at the collection sump, is re-circulated to the heat source.


SLIENT FEATURES :

All structural in HDG Steel to arrest rust
PVC Fills with varying flute sizes of 12 mm, 14 mm, 19 mm, 22 mm to increase the contact surface area.
TEFC, IP-55 Protected 'F' Class Insulated motor with extended shaft to assist outdoor applications.
Adjustable pitch axial flow, dynamically balanced aluminium fans to improve the air exhaust at minimum power usage.
Casings of FRP (Fibre Reinforced Plastics) for durability and strength
All joints fastened with SS fasteners to arrest rust
Uniformity in water dispersion through rotary sprinkler
Capacities 10TR to 600TR , in single cell
Water flow 5 CMH to 500 CMH, in a single cell
360 Degrees air intake area assist 100% cooling efficiency
Delta T (Temperature drop) 4Deg C to 30Deg C, in single cell
ABS Fills for high temperature applications (150Deg C)


ADVANTAGES :

All structural in HDG Steel to arrest rust
PVC Fills with varying flute sizes of 12 mm, 14 mm, 19 mm, 22 mm to increase the contact surface area.
TEFC, IP-55 Protected 'F' Class Insulated motor with extended shaft to assist outdoor applications.
Adjustable pitch axial flow, dynamically balanced aluminum fans to improve the air exhaust at minimum power usage.
Casings of FRP (Fiber Reinforced Plastics) for durability and strength
All joints fastened with SS fasteners to arrest rust
Uniformity in water dispersion through rotary sprinkler
Capacities 10TR to 600TR, in single cell
Water flow 5 CMH to 500 CMH, in a single cell
360 Degrees air intake area assist 100% cooling efficiency
Delta T (Temperature drop) 4Deg C to 30Deg C, in single cell
ABS Fills for high temperature applications (150Deg C)


Applications :

Aluminum dies casting m/c
Air compressors
A/C plant & cold rooms
Blow molding M/c
Chemical industries
Dairy, Citrus and other food processing industries
Distilleries and Breweries plants
Diesel / Gas Genets & Megawatt Projects
Glass Mfg. Plant
Herbal, Aromatics & extraction plants
 


Top Services

Ducted Split Air Conditioners

View More

Air Handling Unit

View More

Chiller Units

View More

VRV System

View More

Panel Air Conditioners

View More

Cooling Towers

View More

Air Washer

View More

Ventilation & Exhaust System

View More

RO water purifier

View More

Ducting Work

View More

Piping (Mild Steel & Copper)

View More

Insulation Work

View More

Cold Chamber

View More

HVAC Contractor

View More

Quick Inquiry